Am J Perinatol 2008; 25(2): 105-109
DOI: 10.1055/s-2008-1040341
© Thieme Medical Publishers

Nasal Continuous Positive Airway Pressure (n-CPAP) Does Not Change Cardiac Output in Preterm Infants

Barbara Moritz1 , Michael Fritz1 , Christian Mann1 , Burkhard Simma1
  • 1Department of Pediatrics, Feldkirch Academic Teaching Hospital, Feldkirch, Austria
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
31. Januar 2008 (online)

ABSTRACT

Our objective was to study how invasive mechanical ventilation impairs cardiac output (CO) in children and adults. Although the application of continuous positive airway pressure (CPAP) is widely practiced in neonatal intensive care, its hemodynamic consequences have not yet been investigated. A prospective study to assess the hemodynamic effects was conducted in 21 preterm infants < 1500 g using two-dimensional M-mode and pulsed Doppler echocardiography during and 1 hour after discontinuation of nasal CPAP (n-CPAP). Gestational age was 28.0 ± 1.9 weeks (mean ± standard deviation); birthweight, 1000 ± 238 g; age at study entry, 200 ± 155 hours; total maintenance fluid, 154 ± 42 mL/kg/day; and n-CPAP level, 4.4 ± 0.9 cm H2O. None of the infants received inotropic support, and n-CPAP did not cause any significant difference in the parameters measured: stroke volume, 3.1 ± 1.0 mL (with n-CPAP) versus 3.1 ± 1.0 mL (without n-CPAP); cardiac output, 487 ± 156 mL/minute versus 500 ± 176 mL/minute; left ventricular diastolic diameter, 1.22 ± 0.15 cm versus 1.24 ± 0.14 cm; fractional shortening, 0.30 ± 0.05% versus 0.29 ± 0.04%; and aortic velocity-time integral, 8.64 ± 1.80 cm versus 8.70 ± 1.65 cm. The n-CPAP level did not influence CO; n-CPAP (up to 7 cm H2O) has no echocardiographically detectable hemodynamic effect in preterm infants. Our data imply there is no need to withhold n-CPAP support to prevent circulatory compromise in these infants.

REFERENCES

  • 1 South M, Morley C J. Respiratory timing in intubated neonates with respiratory distress syndrome.  Arch Dis Child. 1992;  67 446-448
  • 2 In GA. The Cochrane Library, Issue 4, 2002. Oxford; Update Software
  • 3 Ho J J. The Cochrane Library, Issue 4, 2002. Oxford; Update Software
  • 4 Higgins R D, Richter S E, Davis J M. Nasal continuous positive airway pressure facilitates extubation of very low birthweight neonates.  Pediatrics. 1991;  88 999-1003
  • 5 Morley C J. Continuous distending pressure.  Arch Dis Child Fetal Neonatal Ed. 1999;  81 F152-F156
  • 6 Kirchner L, Pollak A. Changing strategy of respiratory support in very low birth weight infants between 1996 and 2000.  Kinderarztl Prax. 2002;  73 31
  • 7 Elgellab A, Riou Y, Abbazine A et al.. Effects of nasal continuous positive pressure (n-CPAP) on breathing pattern in spontaneously breathing premature newborn infants.  Intensive Care Med. 2001;  27 1782-1787
  • 8 De Paoli A G, Lau R, Davis P G, Morley C. Pharyngeal pressure in preterm infants receiving nasal continuous positive airway pressure.  Arch Dis Child Fetal Neonatal Ed. 2005;  90 F79-81
  • 9 Simma B, Fritz M, Fink C, Hammerer I. Conventional ventilation versus high-frequency oscillation: hemodynamic effects in newborn babies.  Crit Care Med. 2000;  28 227-231
  • 10 Kluckow M, Evans N. Relationship between blood pressure and cardiac output in preterm infants requiring mechanical ventilation.  J Pediatr. 1996;  129 506-512
  • 11 Mirro R, Busija D, Green R, Leffler C. Relationship between mean airway pressure, cardiac output, and oxygen blood flow with normal and decreased respiratory compliance.  J Pediatr. 1987;  111 101-106
  • 12 Arnold J H, Hanson J H, Toro-Figuero L O, Gutierrez J, Berens R J, Anglin D L. Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure.  Crit Care Med. 1994;  22 1530-1539
  • 13 Claflin K S, Alverson D C, Pathak D, Angelus P, Bachstrom C, Werner S. Cardiac output determinations in the newborn. Reproducibility of the pulsed Doppler velocity measurement.  J Ultrasound Med. 1988;  73 11-15
  • 14 Hudson I, Hudson A, Aitchison T. Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.  Arch Dis Child. 1990;  65 15-19
  • 15 van den Berg P C, Jansen J, Pinsky M R. Effect of positive pressure on venous return in volume-loaded cardiac surgical patients.  J Appl Physiol. 2002;  92 1223-1231
  • 16 Michard F, Chemla D, Richard C et al.. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP.  Am J Respir Crit Care Med. 1999;  159 935-939
  • 17 Dhainaut J F, Devaux J Y, Monsallier J F, Brunet F, Villemant D, Huyghebaert M F. Mechanism of decreased left ventricular preload during continuous positive pressure ventilation in ARDS.  Chest. 1986;  90 74-80
  • 18 Frazier S K, Stone K S, Schertel E R, Moser D K, Pratt J W. A comparison of hemodynamic changes during the transition from mechanical ventilation to T-piece, pressure support, and continuous positive airway pressure in canines.  Biol Res Nurs. 2000;  1 253-264
  • 19 Pinsky M R, Desmet J M, Vincent J L. Effect of positive end-expiratory pressure on right ventricular function in humans.  Am Rev Respir Dis. 1992;  146 681-687
  • 20 Hsu H S, Chen W, Wang N K. Effect of continuous positive airway pressure on cardiac output in neonates.  Zhonghua Min Guo Xiao Er Ke Yi Xue Hui Za Zhi. 1996;  37 353-356

Barbara Moritz

Department of Pediatrics, Feldkirch Academic Teaching Hospital

Carinagasse 47, A-6800 Feldkirch, Austria

    >