Open Access
CC BY-NC-ND 4.0 · Endoscopy 2019; 07(06): E824-E832
DOI: 10.1055/a-0901-7113
Original article
Owner and Copyright © Georg Thieme Verlag KG 2019

Colorectal endoscopic submucosal dissection can be efficiently performed by a trainee with use of a simple traction device and expert supervision

Daisuke Ide
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
2   Department of Internal Medicine, Division of Gastroenterology and Hepatology, The Jikei University School of Medicine, Tokyo, Japan
,
Shoichi Saito
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
,
Tomohiko Richard Ohya
3   Department of Endoscopy, The Jikei University School of Medicine, Tokyo, Japan
,
Yuske Nishikawa
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
,
Yoshimasa Horie
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
,
Chihiro Yasue
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
,
Akiko Chino
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
,
Masahiro Igarashi
1   Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
,
Masayuki Saruta
2   Department of Internal Medicine, Division of Gastroenterology and Hepatology, The Jikei University School of Medicine, Tokyo, Japan
,
Junko Fujisaki
4   Department of Upper Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
› Institutsangaben
Weitere Informationen

Publikationsverlauf

submitted 18. August 2018

accepted after revision 26. Februar 2019

Publikationsdatum:
12. Juni 2019 (online)

Preview

Abstract

Background and study aims Colorectal endoscopic submucosal dissection (ESD) is technically challenging owing to submucosal fibrosis and difficult endoscope manipulation. Therefore, various traction methods have been reported. We often use a simple looped nylon thread attached to a clip to assist with dissection. We assessed the feasibility of mentor-guided colorectal ESD using this traction device (TD).

Patients and methods From December 2017 to March 2018, we retrospectively reviewed outcomes of 101 colorectal ESDs performed by two groups of endoscopists (A, 5 endoscopists with colorectal ESD experience of < 50 cases; B, 5 endoscopists with experience of > 300 cases). Group A was further divided into two subgroups that performed ESD with or without TD.

Results No significant difference was observed in ESD completion rates (86.1 % [62/72] vs. 96.6 % [28/29]; odds ratio [OR], 0.22; 95 % confidence interval [CI], 0.005 – 1.71; P = 0.17) or procedure times (52.0 min vs. 40.0 min; P = 0.27) and adverse event rates between groups A and B. The rate of TD use was significantly higher in group A than in group B (44.4 % [32/72] vs. 20.7 % [6/29]; OR, 3.03; CI, 1.04 – 10.23; P = 0.03). The completion rate was not different between the two subgroups of group A (with vs. without TD) (81.2 % [26/32] vs. 90.0 % [36/40]; OR, 0.49; CI, 0.09 – 2.29; P = 0.32); however, the proportion of fibrosis cases was significantly higher in the TD-use group (46.8 % [15/32] vs. 22.5 % [9/40]; OR, 2.99; CI, 0.98 – 9.59; P = 0.03).

Conclusion Mentor-guided colorectal ESD using TD was performed efficiently, safely, and in a manner comparable to that of experts.