Background and study aims: Several studies have evaluated the utility of double-balloon enteroscopy (DBE) and capsule endoscopy (CE) for patients with small-bowel disease showing inconsistent results. The aim of this study was to determine the sensitivity and specificity of overtube-assisted enteroscopy (OAE) as well as the diagnostic concordance between OAE and CE for small-bowel polyps and tumors.
Patients and methods: We conducted a systematic review and meta-analysis of studies in which the results of OAE were compared with the results of CE for the evaluation of small-bowel polyps and tumors. When data for surgically resected lesions were available, the histopathological results of OAE and surgical specimens were compared. The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for the diagnosis of small-bowel polyps and tumors were analyzed. Secondarily, the rates of diagnostic concordance and discordance between OAE and CE were calculated.
Results: There were 15 full-length studies with a total of 821 patients that met the inclusion criteria. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were as follows: 0.89 (95 % confidence interval [CI] 0.84 – 0.93), with heterogeneity χ2 = 41.23 (P = 0.0002) and inconsistency (I 2) = 66.0 %; 0.97 (95 %CI 0.95 – 0.98), with heterogeneity χ2 = 45.27 (P = 0.07) and inconsistency (I 2) = 69.1 %; 16.61 (95 %CI 3.74 – 73.82), with heterogeneity Cochrane’s Q = 225.19 (P < 0.01) and inconsistency (I 2) = 93.8 %; and 0.14 (95 %CI 0.05 – 0.35), with heterogeneity Cochrane’s Q = 81.01 (P < .01) and inconsistency (I 2) = 82.7 %, respectively. A summary receiver operating characteristic curve (SROC) curve was constructed, and the area under the curve (AUC) was 0.97.
Conclusion: OAE is an accurate test for the detection of small-bowel polyps and tumors. OAE and CE have a high diagnostic concordance rate for small-bowel polyps and tumors.
This study was registered in the PROSPERO international database (www.crd.york.ac.uk/prospero/) with the study number CRD42015016000.
-
References
- 1 Gay G, Delvaux M. Small-bowel endoscopy. Endoscopy 2008; 40: 140-146
- 2 Rustgi AK. Small intestinal neoplasms. In: Feldman M, Friedman LS, Brandt LI, (eds.) Sleisenger and Fordtran’s gastrointestinal and liver disease. 8th ed. New York, NY: Elsevier; 2006: 2703-2712
- 3 Cangemi DJ, Patel MK, Gomez V et al. Small bowel tumors discovered during double-balloon enteroscopy: analysis of a large prospectively collected single-center database. J Clin Gastroenterol 2013; 47: 769-772
- 4 Moglia A, Menciassi A, Dario P et al. Clinical update: endoscopy for small-bowel tumours. Lancet 2007; 370: 114-116
- 5 Kala Z, Válek V, Kysela P et al. A shift in the diagnostics of the small intestine tumors. Eur J Radiol 2007; 62: 160-165
- 6 Yamamoto H, Kita H, Sunada K et al. Clinical outcomes of double-balloon endoscopy for the diagnosis and treatment of small-intestinal diseases. Clin Gastroenterol Hepatol 2004; 2: 1010-1016
- 7 Kandulski A, Fry LC, Malfertheiner P. Detection of jejunal carcinoid in a patient with obscure-overt gastrointestinal bleeding by double-balloon enteroscopy. Clin Gastroenterol Hepatol 2008; 6: A26
- 8 Iddan G, Meron G, Glukhovsky A et al. Wireless capsule endoscopy. Nature 2000; 405: 417
- 9 Meron GD. The development of the swallowable video capsule (M2A). Gastrointest Endosc 2000; 52: 817-819
- 10 Ginsberg GG, Barkun AN, Bosco JJ et al. Wireless capsule endoscopy: August 2002. Gastrointest Endosc 2002; 56: 621-624
- 11 Yamamoto H, Sekine Y, Sato Y et al. Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointest Endosc 2001; 53: 216-220
- 12 Di Caro S, May A, Heine DG et al. The European experience with double-balloon enteroscopy: indications, methodology, safety, and clinical impact. Gastrointest Endosc 2005; 62: 545-550
- 13 Tsujikawa T, Saitoh Y, Andoh A et al. Novel single-balloon enteroscopy for diagnosis and treatment of the small intestine: preliminary experiences. Endoscopy 2008; 40: 11-15
- 14 Hartmann D, Eickhoff A, Tamm R et al. Balloon-assisted enteroscopy using a single-balloon technique. Endoscopy 2007; 39: E276
- 15 Akerman PA, Agrawal D, Cantero D et al. Spiral enteroscopy with the new DSB overtube: a novel technique for deep peroral small-bowel intubation. Endoscopy 2008; 40: 974-978
- 16 Pasha SF, Leighton JA, Das A et al. Double-balloon enteroscopy and capsule endoscopy have comparable diagnostic yield in small-bowel disease: a meta-analysis. Clin Gastroenterol Hepatol 2008; 6: 671-676
- 17 Liberati A, Altman DG, Tetzlaff J et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol 2009; 62: e1-e34
- 18 National Institute for Health Research. Welcome to PROSPERO: international prospective register of systematic reviews. Available from: http://www.crd.york.ac.uk/prospero/ (Accessed 20 October 2015)
- 19 Nakamura M, Niwa Y, Ohmiya N et al. Preliminary comparison of capsule endoscopy and double-balloon enteroscopy in patients with suspected small-bowel bleeding. Endoscopy 2006; 38: 59-66
- 20 Kameda N, Higuchi K, Shiba M et al. A prospective, single-blind trial comparing wireless capsule endoscopy and double-balloon enteroscopy in patients with obscure gastrointestinal bleeding. J Gastroenterol 2008; 43: 434-440
- 21 Marmo R, Rotondano G, Casetti T et al. Degree of concordance between double-balloon enteroscopy and capsule endoscopy in obscure gastrointestinal bleeding: a multicenter study. Endoscopy 2009; 41: 587-592
- 22 Whiting PF, Rutjes AW, Westwood ME et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011; 155: 529-536
- 23 Moses LE, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med 1993; 12: 1293-1316
- 24 Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med 2002; 21: 1539-1558
- 25 Arakawa D, Ohmiya N, Nakamura M et al. Outcome after enteroscopy for patients with obscure GI bleeding: diagnostic comparison between double-balloon endoscopy and videocapsule endoscopy. Gastrointest Endosc 2009; 69: 866-874
- 26 Fujimori S, Seo T, Gudis K et al. Diagnosis and treatment of obscure gastrointestinal bleeding using combined capsule endoscopy and double balloon endoscopy: 1-year follow-up study. Endoscopy 2007; 39: 1053-1058
- 27 Matsumoto T, Esaki M, Moriyama T et al. Comparison of capsule endoscopy and enteroscopy with the double-balloon method in patients with obscure bleeding and polyposis. Endoscopy 2005; 37: 827-832
- 28 Buscaglia JM, Richards R, Wilkinson MN et al. Diagnostic yield of spiral enteroscopy when performed for the evaluation of abnormal capsule endoscopy findings. J Clin Gastroenterol 2011; 45: 342-346
- 29 Partridge BJ, Tokar JL, Haluszka O et al. Small bowel cancers diagnosed by device-assisted enteroscopy at a U.S. referral center: a five-year experience. Dig Dis Sci 2011; 56: 2701-2705
- 30 Sethi S, Cohen J, Thaker AM et al. Prior capsule endoscopy improves the diagnostic and therapeutic yield of single-balloon enteroscopy. Dig Dis Sci 2014; 59: 2497-2502
- 31 Manno M, Riccioni ME, Cannizzaro R et al. Diagnostic and therapeutic yield of single balloon enteroscopy in patients with suspected small-bowel disease: results of the Italian multicentre study. Dig Liver Dis 2013; 45: 211-215
- 32 Fry LC, Neumann H, Kuester D et al. Small bowel polyps and tumours: endoscopic detection and treatment by double-balloon enteroscopy. Aliment Pharmacol Ther 2009; 29: 135-142
- 33 Vere CC, Foarfă C, Streba CT et al. Videocapsule endoscopy and single balloon enteroscopy: novel diagnostic techniques in small bowel pathology. Rom J Morphol Embryol 2009; 50: 467-474
- 34 Lee BI, Choi H, Choi KY et al. Clinical characteristics of small bowel tumors diagnosed by double-balloon endoscopy: KASID multi-center study. Dig Dis Sci 2011; 56: 2920-2927
- 35 Kamalaporn P, Cho S, Basset N et al. Double-balloon enteroscopy following capsule endoscopy in the management of obscure gastrointestinal bleeding: outcome of a combined approach. Can J Gastroenterol 2008; 22: 491-495
- 36 Li XB, Ge ZZ, Dai J et al. The role of capsule endoscopy combined with double-balloon enteroscopy in diagnosis of small bowel diseases. Chin Med J (Engl) 2007; 120: 30-35
- 37 Ali R, Wild D, Shieh F et al. Deep enteroscopy with a conventional colonoscope: initial multicenter study by using a through-the-scope balloon catheter system. Gastrointest Endosc 2015; 82: 855-860
- 38 Rondonotti E, Pennazio M, Toth E et al. Small-bowel neoplasms in patients undergoing video capsule endoscopy: a multicenter European study. Endoscopy 2008; 40: 488-495
- 39 Riccioni ME, Cianci R, Urgesi R et al. Advance in diagnosis and treatment of small bowel tumors: a single-center report. Surg Endosc 2012; 26: 438-441
- 40 Honda W, Ohmiya N, Hirooka Y et al. Enteroscopic and radiologic diagnoses, treatment, and prognoses of small-bowel tumors. Gastrointest Endosc 2012; 76: 344-354
- 41 Chen WG, Shan GD, Zhang H et al. Double-balloon enteroscopy in small bowel tumors: a Chinese single-center study. World J Gastroenterol 2013; 19: 3665-3671
- 42 Zagorowicz ES, Pietrzak AM, Wronska E et al. Small bowel tumors detected and missed during capsule endoscopy: single center experience. World J Gastroenterol 2013; 19: 9043-9048
- 43 Postgate A, Despott E, Burling D et al. Significant small-bowel lesions detected by alternative diagnostic modalities after negative capsule endoscopy. Gastrointest Endosc 2008; 68: 1209-1214
- 44 Friedrich K, Gehrke S, Stremmel W et al. First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel: a pilot study. J Gastroenterol Hepatol 2013; 28: 1496-1501
- 45 Albert JG, Schülbe R, Hahn L et al. Impact of capsule endoscopy on outcome in mid-intestinal bleeding: a multicentre cohort study in 285 patients. Eur J Gastroenterol Hepatol 2008; 20: 971-977
- 46 Ross A, Mehdizadeh S, Tokar J et al. Double balloon enteroscopy detects small bowel mass lesions missed by capsule endoscopy. Dig Dis Sci 2008; 53: 2140-2143
- 47 Choi H, Choi KY, Eun CS et al. Korean experience with double balloon endoscopy: Korean Association for the Study of Intestinal Diseases multi-center study. Gastrointest Endosc 2007; 66: S22-S25
- 48 Schäfer C, Rothfuss K, Kreichgauer HP et al. Efficacy of double-balloon enteroscopy in the evaluation and treatment of bleeding and non-bleeding small bowel disease. Z Gastroenterol 2007; 45: 237-243
- 49 Pérez-Cuadrado E, Más P, Hallal H et al. Double-balloon enteroscopy: a descriptive study of 50 explorations. Rev Esp Enferm Dig 2006; 98: 73-81
- 50 Almeida N, Figueiredo P, Lopes S et al. Double-balloon enteroscopy and small bowel tumors: a South-European single-center experience. Dig Dis Sci 2009; 54: 1520-1524
- 51 Frantz DJ, Dellon ES, Grimm IS et al. Single-balloon enteroscopy: results from an initial experience at a US tertiary-care center. Gastrointest Endosc 2010; 72: 422-426
- 52 Akamatsu T, Kaneko Y, Ota H et al. Usefulness of double balloon enteroscopy and video capsule endoscopy for the diagnosis and management of primary follicular lymphoma of the gastrointestinal tract in its early stages. Dig Endosc 2010; 22: 33-38
- 53 Chong AK, Chin BW, Meredith CG. Clinically significant small-bowel pathology identified by double-balloon enteroscopy but missed by capsule endoscopy. Gastrointest Endosc 2006; 64: 445-449
- 54 Alexander JA, Leighton JA. Capsule endoscopy and balloon-assisted endoscopy: competing or complementary technologies in the evaluation of small bowel disease?. Curr Opin Gastroenterol 2009; 25: 433-437