Ultraschall Med 2007; 28(1): 45-51
DOI: 10.1055/s-2007-962881
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Best Duplex-Sonographic Criteria for the Assessment of Renal Artery Stenosis - Correlation with Intra- Arterial Pressure Gradient

Beste duplexsonografische Kriterien zum Nachweis einer Nierenarterienstenose - Vergleich mit dem intraarteriellen DruckgradientD. Staub1, [*] , R. Canevascini1, [*] , R. W. Huegli2 , M. Aschwanden1 , C. Thalhammer1 , S. Imfeld1 , E. Singer1 , A. L. Jacob2 , K. A. Jaeger1
  • 1Angiology, University Hospital Basel
  • 2Interventional Radiology, University Hospital Basel
Further Information

Publication History

received: 27.10.2006

accepted: 29.12.2006

Publication Date:
15 February 2007 (online)

Zusammenfassung

Ziel: Die farbkodierte Duplexsonografie (DS) ist eine weit verbreitete Methode zur Untersuchung von Nierenarterienstenosen (RAS). Zur Feststellung einer signifikanten RAS wurden verschiedene Kriterien entwickelt. Das Ziel unserer Studie war der Vergleich zwischen verschiedenen routinemäßig benutzten Kriterien mit intraarteriellen Druckgradienten sowie dem angiografischen Stenosegrad. Ferner wollten wir verschiedene Grenzwerte dieser DS-Kriterien zur Beurteilung hämodynamisch signifikanter RAS validieren. Material und Methoden: Wir analysierten retrospektiv 49 Patienten (Durchschnittsalter 67 Jahre, 29 männlich) mit durch Duplexsonografie dokumentierter RAS, die zur renalen arteriellen Subtraktionsangiografie und Messung des intraarteriellen Drucks überwiesen worden waren (93 Nierenarterien). Die DS-Messung der systolischen Spitzenflussgeschwindigkeit (peak-systolic-velocity PSV) in der Nierenarterie, der Quotient renal/aortaler Flussgeschwindigkeit (RAR) und die Seitenunterschiede der intrarenalen Widerstandsindizes (ΔRI) wurden mit den intraarteriellen Druckmessungen und dem angiografischen Stenosegrad korreliert. Receiver operating characteristics (ROC) wurden benutzt, um den am besten geeigneten Grenzwert der DS-Kriterien festzustellen. Ergebnisse: 39 (41 %) der Nierenarterien waren normal oder hatten nicht-signifikante Stenosen < 50 %, 23 (25 %) hatten eine Reduktion des Durchmessers zwischen 50 % und 69 %, und 31 (33 %) ≥ 70 %. Der systolische Druckgradient zeigte eine gute Korrelation mit dem angiografischen Stenosegrad der RAS (r = 0,77, p < 0,001) und dem in der Duplexsonografie gemessenen PSV (r = 0,67, p < 0,001). Der mittlere systolische Druckgradient (mean systolic pressure gradient) betrug 24 mmHg bei einer 50 %igen Stenose und 23 mmHg bei einer PSV von 200 cm/s. Eine PSV von ≥ 200 cm/s ergab eine Sensitivität von 92 % und eine Spezifität von 81 % für die Feststellung einer RAS von ≥ 50 %. Ähnliche Ergebnisse ergaben sich für eine RAR ≥ 2,5 mit einer Sensitivität von 92 % und Spezifität von 79 %. Diese Grenzwerte haben einen negativen Vorhersagewert von 100 % für den Ausschluss einer hochgradigen RAS von ≥ 70 %. Ein ΔRI von ≥ 0,05 hat eine niedrige Sensitivität von 31 %, aber eine hohe Spezifität von 97 % für die Feststellung einer RAS von ≥ 50 %. Schlussfolgerung: Duplexsonografische Messungen und der Schweregrad der angiografischen Lumeneinengung korrelieren gut mit den systolischen Druckgradienten. Klinisch nützliche DS-Kriterien für die Feststellung einer RAS von ≥ 50 % sind eine PSV von ≥ 200 cm/s oder eine RAR von ≥ 2,5. Diese Kriterien erlauben den verlässlichen Ausschluss einer RAS von ≥ 70 %.

Abstract

Purpose: Colour coded duplex sonography (DS) is widely used for the assessment of renal artery stenosis (RAS). Different criteria have been specified for the detection of significant RAS. The aim of our study was to compare routinely used DS criteria, both with intra-arterial pressure gradients and arteriographic degree of stenosis, and to validate different cut-off points of these DS criteria for the assessment of haemodynamically significant RAS. Materials and Methods: We retrospectively analysed forty-nine patients (median age 67 years, 29 male) with RAS documented by duplex sonography, referred for renal arterial subtraction arteriography and intra-arterial pressure measurement (93 renal arteries). DS measurement of peak systolic velocity (PSV) in the main renal artery, the renal/aortal velocity ratio (RAR) and the side-to-side differences of the intrarenal resistive indices (ΔRI) were correlated to intra-arterial pressure measurements and arteriographic degree of stenosis. Receiver operating characteristics (ROC) were used to determine the best cut-off value of DS criteria. Results: 39 (41 %) renal arteries had normal findings or non significant stenosis < 50 %, 23 (25 %) had a diameter reduction between 50 % and 69 %, and 31 (33 %) ≥ 70 %. The systolic pressure gradient showed good correlation with the arteriographic degree of RAS (r = 0.77, p < 0.001) and the PSV measured by duplex sonography (r = 0.67, p < 0.001). Mean systolic pressure gradient was 24 mmHg at 50 % stenosis and 23 mmHg at PSV of 200 cm/sec. A PSV of ≥ 200 cm/sec provided a sensitivity of 92 % and specificity of 81 % for detecting RAS of ≥ 50 %. Similar results were found for RAR ≥ 2.5 with a sensitivity of 92 % and specificity of 79 %. These cut-off values have a negative predictive value of 100 % for excluding high-grade RAS of ≥ 70 %. A ΔRI of ≥0.05 has low sensitivity of 31 %, but a high specificity of 97 % for detecting RAS of ≥ 50 %. Conclusion: DS measurements and the severity of arteriographic diameter reduction correlate well with systolic pressure gradients. Clinically expedient DS criteria for detecting RAS of ≥ 50 % are a PSV of ≥ 200 cm/sec or a RAR of ≥2.5. These criteria allow reliable exclusion of severe RAS of ≥ 70 %.

References

  • 1 Derkx F H, Schalekamp M A. Renal artery stenosis and hypertension.  Lancet. 1994;  344 237-239
  • 2 Garovic V D, Textor S C. Renovascular hypertension and ischemic nephropathy.  Circulation. 2005;  112 1362-1374
  • 3 Preston R A, Epstein M. Ischemic renal disease: an emerging cause of chronic renal failure and end-stage renal disease.  J Hypertens. 1997;  15 1365-1377
  • 4 Hirsch A T, Haskal Z J, Hertzer N R. et al . ACC/AHA 2005 practice guidelines for the management of patients with peripheral arterial disease (lower extremity, renal, mesenteric, and abdominal aortic): a collaborative report from the American Association for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, and the ACC/AHA Task Force on Practice Guidelines (Writing Committee to Develop Guidelines for the Management of Patients With Peripheral Arterial Disease).  Circulation. 2006;  113 e463-e654
  • 5 Safian R D, Textor S C. Renal-artery stenosis.  N Engl J Med. 2001;  344 431-442
  • 6 Leiner T, Haan M W, Nelemans P J. et al . Contemporary imaging techniques for the diagnosis of renal artery stenosis.  Eur Radiol. 2005;  15 2219-2229
  • 7 Vasbinder G B, Nelemans P J, Kessels A G. et al . Diagnostic tests for renal artery stenosis in patients suspected of having renovascular hypertension: a meta-analysis.  Ann Intern Med. 2001;  135 401-411
  • 8 Arning de C. Ultrasonographic criteria for diagnosing a dissection of the internal carotid artery.  Ultraschall in Med. 2005;  26 24-28
  • 9 Thalhammer C, Aschwanden M, Mayr M. et al . Duplex sonography after living donor kidney transplantation: new insights in the early postoperative phase.  Ultraschall in Med. 2006;  27 141-145
  • 10 Duerschmied D, Rossknecht A, Olsson L. et al . Contrast ultrasound perfusion imaging of lower extremities in peripheral arterial disease - a novel diagnostic method.  Ultraschall in Med. 2005;  26 S39
  • 11 Iacob M, Ifrim S, Tanasescu C. et al . Duplex ultrasound evaluation of patients with carotid stenosis treated with stent implantation.  Ultraschall in Med. 2005;  26 S104
  • 12 Makarenko H S, Nelassov N J, Shepelev A A. Renal artery remodelling in patients with cardiovascular pathology.  Ultraschall in Med. 2005;  26 S39
  • 13 Bardelli M, Veglio F, Arosio E. et al . New intrarenal echo-Doppler velocimetric indices for the diagnosis of renal artery stenosis.  Kidney Int. 2006;  69 580-587
  • 14 Baxter G M, Aitchison F, Sheppard D. et al . Colour Doppler ultrasound in renal artery stenosis: intrarenal waveform analysis.  Br J Radiol. 1996;  69 810-815
  • 15 Conkbayir I, Yucesoy C, Edguer T. et al . Doppler sonography in renal artery stenosis. An evaluation of intrarenal and extrarenal imaging parameters.  Clin Imaging. 2003;  27 256-260
  • 16 Halpern E J, Needleman L, Lack T. Renal artery stenosis. Should we study the main renal artery or segmental vessels?.  Radiology. 1995;  195 799-804
  • 17 Hansen K J, Tribble R W, Reavis S W. et al . Renal duplex sonography: Evaluation of clinical utility.  J Vasc Surg. 1990;  12 227-236
  • 18 Hua H T, Hood D B, Jensen C C. et al . The use of colorflow duplex scanning to detect significant renal artery stenosis.  Ann Vasc Surg. 2000;  14 118-124
  • 19 Krumme B, Blum U, Schwertfeger E. et al . Diagnosis of renovascular disease by intra- and extrarenal Doppler scanning.  Kidney Int. 1996;  50 1288-1292
  • 20 Motew S J, Cherr G S, Craven T E. et al . Renal duplex sonography: main renal artery versus hilar analysis.  J Vasc Surg. 2000;  32 462-471
  • 21 Nchimi A, Biquet J F, Brisbois D. et al . Duplex ultrasound as first-line screening test for patients suspected of renal artery stenosis: prospective evaluation in high-risk group.  Eur Radiol. 2003;  13 1413-1419
  • 22 Olin J W, Pedmonte M R, Young J R. et al . The utility of Duplex Ultrasound scanning of the renal arteries for diagnosing significant renal artery stenosis.  Ann Intern Med. 1995;  122 833-838
  • 23 Radermacher J, Chavan A, Schäffer J. et al . Detection of significant renal artery stenosis with color Doppler sonography: combining extrarenal and intrarenal approaches to minimize technical failure.  Clin Nephrol. 2000;  53 333-343
  • 24 Ripolles T, Aliaga R, Morote V. et al . Utility of intrarenal Doppler ultrasound in the diagnosis of renal artery stenosis.  Eur J Radiol. 2001;  40 54-63
  • 25 Souza de Oliveira I R, Widman A, Molnar L J. et al . Colour Doppler ultrasound: a new index improves the diagnosis of renal artery stenosis.  Ultrasound Med Biol. 2000;  26 41-47
  • 26 Stavros A T, Parker S H, Yakes W F. et al . Segmental stenosis of the ranal artery: pattern recognition of tardus and parvus abnormalities with duplex sonography.  Radiology. 1992;  184 487-492
  • 27 Zeller T, Frank U, Späth M. et al . Farbduplexsonographische Darstellbarkeit von Nierenarterien und Erkennung hämodynamisch relevanter Nierenarterienstenosen.  Ultraschall in Med. 2001;  22 116-121
  • 28 Jaarsveld B C, Pieterman van H, Dijk L C. et al . Inter-observer variability in the angiographic assessment of renal artery stenosis. DRASTIC study group. Dutch Renal Artery Stenosis Intervention Cooperative.  J Hypertens. 1999;  17 1731-1736
  • 29 Gross C M, Kramer van J, Weingartner O. et al . Determination of renal arterial stenosis severity: comparison of pressure gradient and vessel diameter.  Radiology. 2001;  220 751-756
  • 30 Kohler T R, Zierler R E, Martin R L. et al . Noninvasive diagnosis of renal artery stenosis by ultrasonic duplex scanning.  J Vasc Surg. 1986;  4 450-456

5 First and second author equally contributed to the paper.

Dr. Daniel Staub

Angiology, University Hospital Basel

Petersgraben 4

4031 Basel

Phone: ++41/61/2 65 25 25

Fax: ++41/61/2 65 53 56

Email: staubd@uhbs.ch